INC-2026-05-23-001: P16g Power Button Triggers Shutdown Instead of Suspend
Incident Summary
| Field | Value |
|---|---|
Detected |
2026-05-23 ~09:25 PST (observed shutdown sequence after pressing power button to wake from black screen) |
Mitigated |
2026-05-23 (logind drop-in applied) |
Resolved |
2026-05-23 ( |
Duration |
<30 minutes |
Severity |
P3 (Medium) — Unintended full system shutdown on power button press. No data loss due to journaled filesystems, but all open applications and unsaved state terminated. |
Impact |
Complete system poweroff triggered by single short power button press. User expected the press to wake display from DPMS-off state; instead |
Root Cause |
|
Environment
| Property | Value |
|---|---|
Machine |
modestus-p16g (ThinkPad P16 Gen 1) |
OS |
Arch Linux (kernel 7.0.9) |
systemd |
260.1-2 |
Hyprland |
v0.55.2 |
GPU |
NVIDIA GeForce RTX 5090 Laptop GPU (nvidia-open 595.71.05) |
logind.conf |
Default — no overrides, no drop-ins |
hypridle |
DPMS off after 15 minutes ( |
Timeline
| Time | Event |
|---|---|
2026-05-22 10:18 |
Routine |
2026-05-23 ~09:10 |
User walks away from P16g. After 15 minutes, hypridle triggers |
2026-05-23 ~09:25 |
User returns to black screen. Mouse/keyboard input does not wake display (separate incident: INC-2026-05-23-002). User presses power button once expecting display wake. |
2026-05-23 09:25:26 |
|
2026-05-23 09:25:26 |
Full shutdown sequence initiated — Docker, Tailscale, TLP, all services terminated. |
2026-05-23 09:25:29 |
System fully powered off. Filesystems unmounted. |
2026-05-23 ~09:27 |
User reboots, begins investigation. |
2026-05-23 |
|
2026-05-23 |
Fix applied: |
2026-05-23 |
|
Metadata
| Field | Value |
|---|---|
Incident ID |
INC-2026-05-23-001 |
Author |
Evan Rosado |
Created |
2026-05-23 |
Last Updated |
2026-05-23 |
Status |
Resolved |
Trigger |
Power button press during DPMS-off display state |
Fix Location |
|
Post-Incident Review |
Complete |