INC-2026-05-31-001: P16g WiFi Data VLAN 10 Auth Failure
Incident Summary
| Field | Value |
|---|---|
Detected |
2026-05-31 ~15:50 PST (manual discovery — Domus-WiFi-Mgmt-VLAN100 failed, IoT fallback) |
Mitigated |
2026-05-31 ~15:58 PST (connected via Domus-IoT at 10.50.40.166) |
Resolved |
<PENDING> |
Duration |
Ongoing |
Severity |
P3 (Medium) — Workaround available via IoT, but no access to 10.50.1.0/24 network for ISE policy testing |
Impact |
Cannot obtain a 10.50.1.0/24 address via WiFi. Domus-WiFi-Data-VLAN10 has never connected (timestamp 0). Domus-WiFi-Mgmt-VLAN100 failed. Wired connection (Domus-Wired-Mgmt-VLAN100) in config-failed loop. Currently on Domus-IoT (10.50.40.0/24) — no ISE policy match. |
Root Cause |
Under investigation — multiple compounding failures: (1) Data-VLAN10 profile missing MAC randomization disable, (2) Mgmt-VLAN100 and wired profiles failing with config-failed, (3) ISE VLAN assignment may not be configured for WiFi Data VLAN 10 |
Timeline
| Time (PST) | Event |
|---|---|
~15:50 |
Attempted connection to Domus-WiFi-Mgmt-VLAN100 — had been working earlier (static IP 10.50.1.204/24 on VLAN 100) |
~15:53 |
Wired connection (Domus-Wired-Mgmt-VLAN100) auto-activated on enp134s0 — immediately entered config-failed loop (3 rapid failures within 1 second) |
~15:53 |
NM logs show: |
~15:58 |
Supplicant state on wlan0: authenticating → associating → associated → completed (Domus-IoT connected successfully) |
~15:58 |
Domus-IoT assigned 10.50.40.166/24 via DHCP — functional but wrong network for ISE policy testing |
~15:58 |
Wired continues failing: another burst of 4 rapid config-failed cycles |
Post |
|
Symptoms
-
Domus-WiFi-Data-VLAN10:
connection.timestamp: 0— has never successfully connected -
Domus-WiFi-Mgmt-VLAN100: previously working (seen-bssids present) but currently disconnected
-
Domus-Wired-Mgmt-VLAN100:
config-failedin tight loop on enp134s0 — autoconnect retries immediately fail -
Domus-IoT: connected successfully but on wrong subnet (10.50.40.0/24 vs needed 10.50.1.0/24)
-
No wired link detected — ethernet cable may not be connected or NIC not negotiating
Impact Assessment
Systems Affected
| System | Status | Impact Duration |
|---|---|---|
P16g WiFi — ISE policy testing |
Degraded |
Ongoing — cannot reach 10.50.1.0/24 via WiFi |
P16g Wired — 802.1X EAP-TLS |
Failed |
Ongoing — config-failed loop |
P16g general connectivity |
Functional |
N/A — IoT provides internet access |
Business Impact
-
Users affected: 1
-
Data loss: No
-
Workaround: Domus-IoT provides connectivity but ISE policy testing blocked
Metadata
| Field | Value |
|---|---|
Incident ID |
INC-2026-05-31-001 |
Author |
Evan Rosado |
Created |
2026-05-31 |
Last Updated |
2026-05-31 |
Status |
Open — Investigation |
Post-Incident Review |
Pending |