Issues Encountered
Issues Encountered
| # | Issue | Resolution | Status |
|---|---|---|---|
1 |
No native FTD eStreamer connector — Monad does not support Cisco eStreamer protocol for FTD/FMC. Only syslog input available. |
Use syslog forwarding from FMC. Confirmed working with |
✅ Resolved |
2 |
Trial API limitations — Trial account cannot create transforms or outputs via API. UI-only during evaluation. |
Use UI for trial configuration. Full API access available in production license. |
✅ Resolved |
3 |
ISE log splitting capability unknown — Unclear if ISE MnT can route different log categories (RADIUS auth vs accounting vs profiling) to different syslog targets simultaneously. |
Action: test with CHLA ISE team or request Monad support. May require multiple syslog receivers with different ports. |
🔄 Pending |
4 |
SaaS vs on-prem deployment model — Healthcare (HIPAA) may require on-prem deployment. SaaS is simpler but compliance implications unclear. |
Action: CISO decision pending. Monad supports both models. SOC 2 and HIPAA certification status TBD. |
🔄 Pending |
5 |
Sentinel Connector type — Initially unclear whether Monad had native Sentinel integration or required HTTP output configuration. |
Resolved: native |
✅ Resolved |